Hello,

 

Where I work we have Mechanical CAD Librarians who create standard parts such as screws, connectors, etc. These parts are in a folder named 'Standard Parts'. These parts are not modifiable by the Mechanical DE's, which is a good thing.

 

However, in the day-to-day design activities, sometimes these parts unintentionally become 'modified' as far as Windchill is concerned. Not by playing with the part features, but by something as innocent as hiding it in an assembly. (I'm not really sure what leads up to this status change, since I'm not staring at Workspace after every thing I do) This means the parts cannot be uploaded to the Server. Sometimes they are marked as 'ineligible for upload', 'modified', 'upload required' or even NEW. There are the various ways to deal with this, 'Make Read Only', 'Update' etc. , but sometimes the part is so out of whack, the only way to fix it is to check the part back out from the Library ONE AT A TIME. This can be very tedious. I know sometimes you can delete the bogus part out of the Workspace, but even then, it sometimes requires that the part be deleted from it's assembly first.

 

So I'm not looking for ways to deal with these issues when they pop up, I know how to do that. I know I can set part status to 'LOCK', but even this is tedious when it has to be done every time I bring an assembly out from the Library.

 

What I am looking for is IF there is a way to set a Directory/Folder up so that when parts are retreived from it they are automatically set to 'LOCK', thus preventing any false modification and status change in the Workspace, and if there is a way to do that, HOW do I do that?

 

Thanks!

 

ML

 

Using WF4 M030 Windchill PDMLink 9.0


No-Gap Numbering?

$
0
0

Has anyone had any luck setting up a source of numbers that does not drop numbers or otherwise create gaps in the sequence?

Defining Lifecycles: Help!

$
0
0

We are currently on Windchill 10.1 and are running a pretty OOTB configuration.  We are also starting a project looking at configuration changes and small customizations that we can do to make life easier.

 

One of the things we "THINK" we would like to change is our OOTB lifecycle.  I know the mechanics of the lifecycles, states, promotes, revising, etc..  But not the WHY part of it. 

 

So for example, in the design process we start with alphabetic revisions and then switch to numeric revisions at release to production.

 

Most of the engineers want a very simple lifecycle [Design][Released][Canceled].

 

I am trying to make the arguement that since our business needs are to have a 2 phase revision scheme that we need a 2 phase lifecycle with alpha first and then numeric. [Design][Alpha Released][Numeric Released][Canceled].

 

I lack the knowledge to give them sufficient reason to accept the more complex lifecycle.  Any information or resources I could go look at that will help to answer the question: WHY?

 

-marc

Display link attribute in relatedItems tab

$
0
0

Hi.

Is it possible to dislay some WTPartDescribeLink attribute as column in Described By Documents table on WTpart page?

Thanks.

How to get text field values in formProcessor?

$
0
0

Hi!

Anybody know how to get text field values, that i was inserted in some wizard, in the formProcessor that will handle this wizard?

When to use Secondary Content (Attachments)?

$
0
0

For Document management in Windchill, I am seeking input on when to use Primary vs. Secondary Content as well as Object naming, in general.  First, with regards to Object Naming, some are recommending we name a Document record 123TBD.docx while others recommend simply 123TBD (w/ no file extension).  Note the Primary Content in this example would be the 123TBD.doc.  Also, if there is a 123TBD.xls which supports this document some are recommending we include this as Secondary content while others recommend creating a 123TBD WT Part along with a 123TDB.xls document record and associate both the .doc and .xls objects to the WT Part.   Any thoughts on this subject are greatly appreciated.  Thank you in advance!

Step to edit a priciapal from participent Adminstrator

$
0
0

please anyone give steps to edit priciapl from participent administrator of windhill 10.2 M010 PDMLink solution.

Display of part state on drawing

$
0
0

Hi,

 

Our drawing formats have a field to display the state of the model (PTC_WM_LIFECYCLE_STATE).  When we promote a part to released, this field displays "Released".  This looks funny as all other text on the format and in the drawings is all caps.  Is there a way to change the way this parameter is displayed in the released state from "Released" to "RELEASED"?

 

Thanks.


Desktop Integration and office documents

$
0
0

We have many .docx documents that we want to maintain in Windchill (10.2). These documents however have links to other documents (e.g. "see this document for more information regarding X").

 

Is this also possible when the documents are in Windchill?

 

And if it is possible, how do we know that the link points to the latest version of the document?

 

Thank you!

Need API and method to change the Cad to part relationship from "CONTENT' to "OWNER"

$
0
0

Hi ,

 

I created the EPM Build relationship between parts and CAD using the API EPMDescribelink.This method created the " CONTENT" relationship between the part and CAD by default.

 

Beacuse of this I am not able to add the Part in structures.

 

Is there any API and method that finds the relationship between CAD part and associated Windchill Part.What is the method to change this relationship from "CONTENT" to "OWNER"

 

Appreciate the help.

 

Thanks.

Action validator for standard windchill actions

$
0
0

Hi.

I need to hide "relatedPartsDocuments" and "relatedPartsCADDocuments" tables from info page of wtpart softtype (an only for this softtype).

How should i define UIComponentValidator not to brake standard behavior of these tables?

I know how i can get action name and softtype id in UIComponentValidator. The question is how not to affect standard display settings for other softtypes?

Thanks.

Set parts to 'LOCK' status upon retrieval from Library?

$
0
0

Hello,

 

Where I work we have Mechanical CAD Librarians who create standard parts such as screws, connectors, etc. These parts are in a folder named 'Standard Parts'. These parts are not modifiable by the Mechanical DE's, which is a good thing.

 

However, in the day-to-day design activities, sometimes these parts unintentionally become 'modified' as far as Windchill is concerned. Not by playing with the part features, but by something as innocent as hiding it in an assembly. (I'm not really sure what leads up to this status change, since I'm not staring at Workspace after every thing I do) This means the parts cannot be uploaded to the Server. Sometimes they are marked as 'ineligible for upload', 'modified', 'upload required' or even NEW. There are the various ways to deal with this, 'Make Read Only', 'Update' etc. , but sometimes the part is so out of whack, the only way to fix it is to check the part back out from the Library ONE AT A TIME. This can be very tedious. I know sometimes you can delete the bogus part out of the Workspace, but even then, it sometimes requires that the part be deleted from it's assembly first.

 

So I'm not looking for ways to deal with these issues when they pop up, I know how to do that. I know I can set part status to 'LOCK', but even this is tedious when it has to be done every time I bring an assembly out from the Library.

 

What I am looking for is IF there is a way to set a Directory/Folder up so that when parts are retreived from it they are automatically set to 'LOCK', thus preventing any false modification and status change in the Workspace, and if there is a way to do that, HOW do I do that?

 

Thanks!

 

ML

 

Using WF4 M030 Windchill PDMLink 9.0

Display link attribute in relatedItems tab

$
0
0

Hi.

Is it possible to dislay some WTPartDescribeLink attribute as column in Described By Documents table on WTpart page?

Thanks.

Multiple caches problem.

$
0
0

Hello,

 

Me and my colleagues have had this issue for some time now.

 

Everytime we open several instances of ProE with PDM Link, the application opens up in a different cache that is created on our C:\ drive: "PROD", "PROD_1", "PROD_2" etc.

Is there any way we can control in which cache to open ProE, or is there a way to switch between the caches? Or in fact could we have just one fixed cache everytime we open ProE?

This is very frustating because when we're modifying a part and we need to have the original opened up separately for troubleshooting with another ProE session, we cant find the latest Workspace because it's in a different cache.

 

Also when we start work again it's very hard of keeping track in which Workspace we worked in the past, if it was in a different cache, and where exactly is the latest saved version.

 

We are using Creo Elements(WF5) M210 64bit, with PDMLink 10.0 and we will upgrade to 10.2.

 

Thank you in advance.

How to edit the Display Name and description of a document type in 9.1 ?

$
0
0

I am looking to edit the Display Name and Description of a Document type in 9.1 M060.

PTC TS suggests to use a xml loader. But the Prerequisite for that is to keep the logical identifier as empty before loading.

 

I am looking to update the database tables instead.

I updated the display name and description for the particular document type in WTTYPEDEFINITIONMASTER.

 

Still it does not help.

 

Is there anything pending for the change to reflect at UI level?

 

This Information will be of great help.

 

Thanks & regards,

Prabhu


Visualization Representation Failed.....

$
0
0

Hi All,

               I am using Windchill 10.1 M040 with Creo Parametric 2.0. When I am pulishing to create a new representation using windchill it always fails with the log. Whenever I checked in from Creo Parametric its successfull. In Windchill the CadWorker is configured properly and run successfully how ever I can't generate the new Representation for the files. the log is below. kindly help. i tried it also using Administrator but always fail. the CadWorker is running.

 

Thanks

 

ul 1, 2014 12:55:04 AM:make temp dir D:\ptc\Windchill\Windchill\temp\pubtemp\publish7689743143708481417.tmp

Jul 1, 2014 12:55:04 AM:Start Job: Assembly  - chair.asm, 1.1

Jul 1, 2014 12:55:04 AM:"As Stored" Config Spec is available

Jul 1, 2014 12:55:04 AM:The EPMDocument As Stored Config Spec was selected as the default

Jul 1, 2014 12:55:04 AM:Start: Assembly  - chair.asm, 1.1

Jul 1, 2014 12:55:04 AM:Authoring Application: Creo

Jul 1, 2014 12:55:04 AM:Use Extended Positioning Assembly Processing

Jul 1, 2014 12:55:04 AM:Transferring Files to: D:\ptc\Windchill\Windchill\temp\pubtemp\publish7689743143708481417.tmp

Jul 1, 2014 12:55:04 AM:Error: Unable to Authenticate. Contact your system administrator and review the Method Server log for more information.

Jul 1, 2014 12:55:04 AM:Number of Files (identified to be) Transferred: 0

Jul 1, 2014 12:55:04 AM:No content to process

Jul 1, 2014 12:55:04 AM:End: Assembly  - chair.asm, 1.1

Jul 1, 2014 12:55:04 AM:End job (with error): Assembly  - chair.asm, 1.1

Jul 1, 2014 12:55:04 AM:Publish Complete event dispatched

Jul 1, 2014 12:55:04 AM:remove temp dir: D:\ptc\Windchill\Windchill\temp\pubtemp\publish7689743143708481417.tmp

user rights --> move

$
0
0

All our normal users can't move WTParts and WTDocuments, only the admin can do this. Where can I change this?

Positioning Assemblies vs Extended Positioning Assemblies

$
0
0

We are currently switching to positioning assemblies when publishing Catia and Creo. I understand that "extended" positioning assembies should be used for Creo, if there are assembly features.

 

Please would sombody mind to explain technically what the difference is, and roughly what is happening in the background?

What are the downsides of using "extended" positioning assemblies, over standard positioning assembies?

 

I've read a few presentations on this subject, but have yet to find anything which addresses this particular question.

 

Many thanks - Darren

White screen issue

$
0
0

Hi everybody,

 

Have anyone ever face this issue:

In Windchill embedded browser environment, when do Add objects to workspace/Check in/Check out, it turns to blank white screen with no response, and then click "Refresh" (in the right of the address bar), it will return back to workspace, but the previous action didn't performed, and then redo Add objects to workspace/Check in/Check out, and this time it succeed. I am running Creo2.0 and Windchill 10.2.

 

Any help will be appreciated!

Rick

Addcolumns utility - How to fix Column size both codebase and db(oracle)

$
0
0

I am testing Addcolumns utility for add HardType Property(column) to wt.part.WTPart.

 

1) AddColumns-a wt.part.WTPart String=1 stringSize

or AddColumns-a wt.part.WTPart String=1

 

2) Server start  >  site menu > Utility > Type and Property  > add Property

 

3) AddColumns-repair wt.part.WTPart

 

4) AddColumns-r wt.part.WTPart

result =>-------------------------------------------------------------------------------------------------------------

wt.part.WTPart: Database columns are matched with codebase columns.

Database columns: String=2, Long=0, Double=0, Boolean=0, Timestamp=0, ObjectRef

erence=0, VersionReference=0, InlineBLOB=0

Codebase columns: String=2, Long=0, Double=0, Boolean=0, Timestamp=0, ObjectRef

erence=0, VersionReference=0, InlineBLOB=0

Allocated columns: [typeInfoWTPart.ptc_str_1, typeInfoWTPart.ptc_str_2]

Source file: D:\ptc\TK_Windchill_10.2\Windchill\temp\src\wt\part\WTPartTypeInfo

.java exists.

Source file columns: String=2, Long=0, Double=0, Boolean=0, Timestamp=0, Object

Reference=0, VersionReference=0, InlineBLOB=0

Database string column size: 4000

Codebase string column size: 4000

--------------------------------------------------------------------------------------------------------------------------

 

I want to Column Size more small  => typeInfoWTPart.ptc_str_1 : 300byte and typeInfoWTPart.ptc_str_2 : 500byte

 

- How to reconfiure string column size both Codebase and Database when I command "AddColumns-r wt.part.WTPart" ?