Quantcast
Channel: PTC Community : All Content - Windchill
Viewing all 6049 articles
Browse latest View live

Publishing not happening between set states?

$
0
0

When we change the status of drawing, the worker doesn't publish the drawing. This was not the behavior before and we have to manually click on the thumbnail to create the representation. Could someone  provide me inputs as to where to begin investigating the cause of this issue.


Windchill SUMA- Error while the Vendor Part is being created.

$
0
0

Hi All,

 

I had been trying to create a Vendor Part from the new part window. But I am getting an error like

 

Caused by: (com.ptc.windchill.suma.axl.axlResource/153) com.ptc.windchill.suma.axl.AXLException: Organization "SUMA1 (Site)" is not a Vendor organization

 

i was able to create a Manufacturer Part but not a Vendor Part. So can anyone help me regarding this ?

 

Thanks and Regards,

Aditya Achanta

Is there any way to add comments to a previously checked in iteration?

API for publishing additional formats

$
0
0

Hi, Is there an API to publish the additional format like step, iges, x_t for an epm document?

Vault Archiving

$
0
0

My organization is currently in the process of deploying a Windchill 11 environment. Are there any preferred and supported solutions for archiving vault data as we are expecting a large data store of around 50 + TB

 

Any suggestions would be greatly apprecated

When creating a Problem Report can I limit the Select Affected Objects to WTparts only?

$
0
0

I want to limit users from linking directly to the CAD objects (or other files for that matter). How can I set it so only WTparts appear when adding items to the Select Affected Objects section?

 

Thanks in advance

Adam

updating the partname with loadfromfile

$
0
0

Hello,

 

in Windchill 10.2 I want to update the name of a part with the loadfromfile method in the Windchill Shell using BeginCreateOrUpdateWTPart (found in csvmap file). The method server ouputs that all objects have been loaded successfully, when I invoke the update of the name. But when I look at the part information, I can only see the the iteration has been increased but no change in the name. Do I miss something?

 

Best regards

Ali

WPA says that the RoHS exemptions will expire July 22 2016. I do not think it is correct, what to do?

$
0
0

In WPA, when you go into manage compliance for RoHS it states for all exemptions that they will expire on July 22 2016. To my knowledge is this valid only for exemption 7b, all the others are still under evaluation. How are you managing this situation? We have component responsible persons all over the world, and they have started to act on this information.


Anyone setup PTC Navigate on Thingworx yet?

$
0
0

I have it 90% setup I think.  When I activate the single sign on it bounces to my windchill server to login in.  It then bounces back to my Thingworx server but I get an error.  Error is to many redirects.  I thought this might just be a browser issue but I have tried all the tricks for fixes I found on line.  As you can guess they did not work.  Any help would be great.  FYI it does kind of work if I don't turn on single sign on.  Although I my search results are hit and miss.  I am on Windchill 10.2 M020.

How to edit folder level security permissions?

$
0
0

I am part of product manger and still don't get the permission to edit security from actions menu at folder level. Should I be part of some other group as well to be able to do this action?

How to do to run a validator for CAD objects for the SaveAs command and Rename

$
0
0

Hi


I need to
validate theparameter"number" inWindchillfor CAD objects and partswhenare performedSaveAs and Renamecommand.

Createdvalidatorclass in whichredefined thefunctions - validateSelectedAction(), validateSelectedMultiSelectAction() and validateFormSubmission()


What is the "action"I need to usetoregister thevalidatorclass?

What do I need to specify the "selector" to the calling function validateSelectedAction(), validateSelectedMultiSelectAction() and validateFormSubmission()


I triedto doas shown below, butare not calledvalidators.


<Service context="default" name="com.ptc.core.ui.validation.UIComponentValidator" targetFile="codebase/service.properties">

        <Option requestor="null" serviceClass="ext.ntck.validators.NTCKValidator" selector="WFSAVEAS" />

        <Option requestor="null" serviceClass="ext.ntck.validators.NTCKValidator" selector="MULTIRENAME" />

</Service>

 

Thanks.

What is the importance of cache files?

$
0
0

Hello All,

 

Being new to the Windchill / Creo administration arena I have noticed that in most cases when one of our users has a problem starting Creo or connecting to a Workspace in Windchill, it boils down to an issue with corrupt cache files. So my questions is what is the importance or significance for the cache folder/files and why are these not cleaned up when the user exits Creo / Windchill?

 

Thank you.

 

Regards,

Thom

Representation creating but not visible in Pdmlink

$
0
0

We are working in creo elements pro5.0 and windchill pdmlink 9.1, we have strange issue since yesterday that the representations of the models are created correctly but not visible in pdmlink.

Brief description:

Models are saved in pdmlink and when generated representations it create pvs, pvp and pdf files. But since yesterday only pvs and pvp files are getting created and no pdf.

The logs also didn't show much information.

We are also checking exactly what has been changed in the system in past 1 or 2 days, but there was no significant event occurred.

Thanks to provide any suggestion.

How do you create a Library in Windchill

$
0
0

Is there a document that will show you how to create a library in windchill.

Thingworx Windchill extension

$
0
0

I am exploring Windchill extension on Thingworx. PTC has built out of the box functionality to access windchill data using infoengine. I did not find much on REST implementation.

 

Has anybody found a documentation on Windchill REST framework.

 

:-)

Preeti


Linking Windchill Document to table on drawing

$
0
0

I have a excel document that I checked into Windchill.  How do I create a table on Creo drawing to automatically update if excel file updates.

 

Or is it possible?

 

Thanks,

 

Brock

New Windchill Document creation error

$
0
0

Dear Windchill Users,

 

We are planning to upgrade from Windchill8.0M030 to mostly 11.0 but before that facing the following error in new Windchill document creation.

 

New Document creation error:

For new active products as well as for products for which new document creation was working in the past, currently the new document creation is not working (New WTPart creation and checkin is working fine)

 

Create a new WTDocument in the PDMLink folders using the following menu and upload a plain text document.

 

ERROR:


There is no trace in the Method Server log after this error (log attached) This was working in the past. Please let me know why a library is required if there is an active product and if this is a client related issue and how it can be solved.

 

Thanks,

Amol

 

Alicon Group (Silicon Meadows Design Limited)

What happened to the Customer Experience Management CDs for Windchill 10.2 and previous?

$
0
0

Hello,

 

I must have missed a memo or announcement or something.

 

A few months ago, I was able to find the Customer Experience Management CDs on the download site under "Windchill Quality Management System (CAPA, NC etc.)"

 

Now, the only version available is for Windchill 11.

 

Where did MED-60744-CD-102 (and previous releases) go?  (as seen in http://support.ptc.com/cgi/support/apps/sft_upd_dsp/sft_upd_dsp_adv.pl?product=NRM)

 

Thank you.

 

MLS

Problems Registering Windchill Server

$
0
0

Hi,

We're trying to set up Windchill. We have a Windchill account and can log into it, but we're having issues registering our server in Creo. We had previously managed to register a server, and this is still on our list, but it says "offline" and we can't select it. We tried to register a new server, but after typing in our name and location fields into the boxes (using the location provided in the Windchill Practical Guide for FIRST), messages pop up, saying "Invalid server location. Please change the 'Location' field and try again." and "You have no workspace to register. You cannot register this server without a workspace."

Thanks for any help help you can offer.

Perform Mass Change

$
0
0

When performing a Mass Change - Replace Existing Part, all Custom Part Usage IBA values are automatically filled in.  When choosing Insert Existing Part, none of the Custom Part Usage IBA values are filled in.

 

Is there an easy way, configuration without customization, to add Custom Part Usage IBAs to this Mass Change Window?

 

If the system would use the Default value for these Part Usage IBAs, defined in the Type and Attribute Manager, it would be fine too.

 

Windchill 10.1 M030