Clik here to view.

Applet not loading in Workgroup manager

Hey guys,     I've been mucking with this for a day or so now. I installed the workgroup manager for Windchill 10.1, and everything was fine. I believe this started after I installed Creo View....

View Article


Windchill 9.1 m070 with Creo 2 Compatibility

Hi Is there anyone using Windchill 9.1 m070 with Creo 2 latest datecode? I want to know about the compatibility. Please reply. RegardsK.Mahanta

View Article


Windchill Calendar: Delegate

Is it possible to delegate your tasks to a group rather than an idividual user through the caldendar? One thing that I have noticed and I'm wondering if anyone is experiencing this, when I try to get a...

View Article

CNs and Resulting Objects across containers issue

I'd like to know if anyone has addressed the following issue... Use Case:   A CN could contain resulting objects from more than one container.  The problem is that the CN resolves the roles based on...

View Article

How to get folder of checked out part?

Hi.I need to put created child parts to the parent part folder (all i do through java code).If parent part wasn't checked out, then folder is defined corrrectly ( for example:...

View Article


Creo View Lite fails to open files

Thanks in advance for any helpful recommendations. We recently upgraded Product View to Creo View Lite 2.0, datecode M040 build 15.This has not been a good experience.Many of our drawings will not open...

View Article

Webroot SecureAnywhere & Windchill Cache

I posted this several months ago over on ptcuser but didn't get any responses.  Posting here to see if I can get any feedback.  Thanks. Currently IT is experimenting with replacing McAfee Virus scan...

View Article

WTPart Structure Visualization Tab

It appears the visualization tab in the structures browser window is very unstable. I have it open in IE and Chrome and in Chrome it displays a representation of the wrong graphics. The in IE the...

View Article


checkin error

"A referential integrity violation occurred for this operation"  i got this error while doing check in process.. and check in failed  please any one suggest solution for this

View Article


Basic retrieval of data using Java/SOAP?

My organization has an existing installation of Windchill and PDMLink and we are interested in integrating the Part and BOM data from those systems with third-party systems in the Enterprise. Our...

View Article

Citrix and Desktop Integration (DTI) - who has a need for this?

Desktop Integration (DTI) isn't supported for use in Citrix (multi-user environment).  What happens is that the first user that logs in and starts using DTI, the process works for them but not...

View Article

Should Windchill have an Easy Tool to create Custom Publishing Jobs

Should Windchill have an Easy Tool to create Custom Publishing Jobs? PTC's Classic Graphics Server had a very easy tool; the Equivalent of Creating an Advanced Search in Windchill;  Windchill offers us...

View Article

How do I ensure the MFG Team views only Released Drawings

I need to ensure the MFG Team views only Released Drawings . I modified the Lifecycle state's Access Control and unchecked all permissions for Released State for MFG team . But the policies aren't...

View Article


How to add custom jar to Windchill

Hi.What is best practice for adding custom jar to Windchill?Should i put it anywhere and add path to wt.java.classpath property in wt.properties?Or should i put it in codebase/WEB-INf/lib...

View Article

How to create a subscription to object events into a worklow ?

I would like to automatically create a subscription to object events inside a workflow, using java code.looking into the windchill class documentation, I found that I should probably be using the...

View Article


deleting wt part from database

How to delete wtpart from database? I have deleted this 100-100-110 wtpart number from GUI. While renaming 100-100-220 by 100-100-110 giving error. Number is not unique. In GUI if I search for wtPart...

View Article

Check in error

My company is pretty new to Windchill we are using version 10.1 M040.  One of my users got this error when trying to check in a part. The transaction log for database 'WindchillDB' is full. To find out...

View Article


Deleted Part

Have a user who deleted a part that wasn't supposed to be deleted.  Can someone give me the process to recover just that one part? Is there a way to get it from version history? Thanks in Advance

View Article

Batch EPMdocument export

Is it possible to export specfied EPMDocument(with all references) from PDMLink in batch mode to local disk?

View Article

Image may be NSFW.
Clik here to view.

where are my favorites in Windchill 10?

Hello.  I have searched in help within Windchill 10 and online but cannot seem to find where my Favorites end up when I follow the fairly simple process as depicted below:  or in ptc's support site:...