filter drawing of an assembly
Hello is it possible to filter only the drawings of an assembly and all his sub assembly in structure.Or there are a way to see all the assemble inside an assembly? thank
View ArticleCreo View Adapter for SolidWorks Plots Upside Down
Curious if anyone has successfully implemented the Creo View Adapter for SolidWorks when outputting HPGL (.plt) files. I've followed all the instructions and my plots are coming out upside down. I'm...
View Articleconditional constraint issue
hi all, how to write conditional constraint to achieve as follow Two attributes:ATTRIBUTE_1 (CAR_BRAND) & ATTRIBUTE_2 (MODEL).Value of ATTRIBUTE_1 could be:- VALUE_1 (BMW) or VALUE_2 (AUDI) Value...
View ArticleWQS Reliability Prediction 217F - Parts Stress
The Relex 2011 Reference manual (11-353) handbook shows the stress parameters to be included when conducting parts stress reliability analysis.The operating voltage parameter (Real (Volts) shows that...
View ArticleHow do I change the Event Type from Undeveloped Event to Basic Event on a...
I have an FTA tree with a repeated "undeveloped event". After researching and entering the correct failure rate, I would like to change all instances to "Basic Event", however, the Gate/Event Type...
View ArticleResource needed for the entry information about the Part Stress Anaylsis of...
Hello Experts, We are having difficulty to fill some parametrs in part information that will be used in Part Stress Analysis in Windchill Quality Solutions Prediction module in accordance with...
View Articledifferent duty cycles for parts in an assembly
Hello everyone, for a system I'm modeling in WQS right now, I have the situation that some assemblies of the system contain parts with different duty cycles. Those duty cycles should be considered for...
View ArticleProductivity Enhancements on Windows Explorer Integration for Windchill...
In Windchill 10.2 a lot of effort has been made to enhance and simplify the user experience when working with WTDocuments from your Microsoft Windows Desktop.In this blog I will show you some of the...
View ArticlePart II Enhancements on Windows Explorer Integration for Windchill Desktop...
In my last blog post Productivity Enhancements on Windows Explorer Integration for Windchill Desktop Integration 10.2, Part I I discussed the possibilities and enhancements around the Windchill...
View ArticleHow to determine the number of unique part numbers site wide in Windchill?
Hello all, In order to support a business decision, I have need to determine a unique count of drawings, parts, and assemblies. PTC support has offered the following sql query, but the numbers don't...
View ArticleMPMLink New Part Not Reading OIR
10.1 M040 Hi Everyone,I am really struggling with this issue and I cannot figure out why it is happening. I have a soft type of WTPart called SCPart. I have an OIR for SCPart at the Org level. When...
View ArticleHow to make "template" field as required in New Change Notice Window.
How to make "Template" field as required in New Change Notice Window.
View ArticleEU RoHS substances per Directive 2015/863 amending Directive 2011/65/EU...
What's the plan for a spec release for RoHS substances per Directive 2015/863 amending Directive 2011/65/EU to cover below. We already have customers asking to comply with this. Substance...
View ArticleREACH June 2015 SVHC - Verdict error in WPA
Reach SVHC June 2015 release added two substances for which CAS number is not defined unlike the other substances. Currently WPA is checking for the string...
View ArticleCurrent Assignee on Details page of Change Notice/Activity/Request
Is there a way to get the current assignee of a Change task onto the details page of that task. It could be a Change Notice, Change Activity, Change Request, Problem Report, etc. Basically anything...
View Articlewt.util.WTRemoteException only in cluster environment when using windchill API
Hi, I have written a utility class in windchill and trying to access the methods of that java class outside windchill application using the below code....
View ArticleWindchill and SiteMinder software
We are working with SiteMinder so our users will have one less click(what will the folks do with all of that free time!) but because Windchill(PDMLink 10.2 M020) uses the '#' sign as an anchor...
View ArticleImport/Export Manager.
Hi,I am using OOTB Export/import framework to do transaction(Export/Import) between two Windchill server's. I am facing an issue where importer say's Part in Part structure not found pointing to link...
View ArticleWindchill Quality Solutions 10.1 - Part Libraries
Hi, I am a Component Engineer and use Windcihll Quality Solutions for MTBF prediction. One major issue I found is that a number of parts are not available in any of the part libraries. When I "check...
View ArticleRelex Severity, Occurrence, and Detection Customization
Can anyone point me in the right direction to customize Sev, Occ, and Det in the FMEA? Thanks!
View Article